MbusDataTableInterfacereadInputRegistersTable Method |
Namespace: FieldTalk.Modbus.Slave
protected virtual bool readInputRegistersTable( int startRef, short[] regArr )
Protected Overridable Function readInputRegistersTable ( startRef As Integer, <OutAttribute> regArr As Short() ) As Boolean
protected: virtual bool readInputRegistersTable( int startRef, [InAttribute] [OutAttribute] array<short>^ regArr )
false indicates that access has been denied or is out of range. The Server Engine will reply to the master with an exception reply message
Required: Yes
Default Implementation: Returns false which indicates to Server Engine that this address range is unsupported.
protected override int readInputRegistersTable(int startRef, short[] regArr) { return readHoldingRegistersTable(startRef, regArr); }
Protected Overrides Function readInputRegistersTable(ByVal startRef As Integer, ByVal regArr() As Short) As Integer Return readHoldingRegistersTable(startRef, regArr) End Function
No code example is currently available or this language may not be supported.