Documentation
|
FieldTalk Modbus Slave C++ Library
Library version 2.11.0
|
This class realises the server side of the MODBUS/TCP slave protocol. More...
Public Member Functions | |
| MbusTcpSlaveProtocol () | |
| Instantiates a MODBUS/TCP protocol server object. More... | |
| int | startupServer () |
| Puts the Modbus server into operation. More... | |
| int | startupServer (const char *const hostName) |
| Puts the Modbus server into operation. More... | |
| void | shutdownServer () |
| Shuts down the Modbus server. More... | |
| int | serverLoop () |
| Modbus slave server loop. More... | |
| int | setConnectionTimeOut (long masterTimeOut) |
| Configures connection time-out. More... | |
| long | getConnectionTimeOut () |
| Returns the connection time-out setting. More... | |
| void | installMasterDisconnectCallBack (void(*f)(void *userData, const char *masterIpAddrSz, DisconnectReason reason), void *userData) |
| This function installs a callback handler to be called in the event of a master disconnection. More... | |
| int | addDataTable (int slaveAddr, MbusDataTableInterface *dataTablePtr) |
| Associates a protocol object with a Data Provider and a Modbus slave ID. More... | |
| int | getConnectionStatus () |
| Checks if a Modbus master is polling periodically. More... | |
Static Public Member Functions | |
| static const TCHAR * | getPackageVersion () |
| Returns the library version number. More... | |
Protected Member Functions | |
| int | readHeader (int sockIdx) |
| Sub-routine to read and validate the Modbus/TCP header. More... | |
| int | readPayload (int sockIdx, int result) |
| Sub-routine to read and validate the Modbus/TCP payload. More... | |
| void | terminateSocket (int sockIdx, DisconnectReason reason) |
| Sub-routine to manage termination of connection. More... | |
Protocol Configuration | |
| int | setTimeout (long timeOut) |
| Configures master activity time-out supervision. More... | |
| long | getTimeout () |
| Returns the currently set master activity time-out value. More... | |
| void | disableExceptionReplies () |
| Supress exception replies to be sent. More... | |
| void | enableExceptionReplies () |
| Enables exception replies after they have been turned off. More... | |
Transmission Statistic Functions | |
| unsigned long | getTotalCounter () |
| Returns how often a message transfer has been executed. More... | |
| void | resetTotalCounter () |
| Resets total message transfer counter. | |
| unsigned long | getSuccessCounter () |
| Returns how often a message transfer was successful. More... | |
| void | resetSuccessCounter () |
| Resets successful message transfer counter. | |
TCP/IP Server Management Functions | |
| int | isStarted () |
| Returns whether server has been started up. More... | |
| int | setPort (unsigned short portNo) |
| Sets the TCP port number to be used by the protocol. More... | |
| void | installIpAddrValidationCallBack (int(*f)(const char *masterIpAddrSz)) |
| void | installIpAddrValidationCallBack (int(*f)(void *userData, const char *masterIpAddrSz), void *userData) |
| This function installs a callback handler for validating a master's IP address. More... | |
| void | installMasterPollNotifyCallBack (int(*f)(const char *masterIpAddrSz)) |
| void | installMasterPollNotifyCallBack (int(*f)(void *userData, const char *masterIpAddrSz), void *userData) |
| This function installs a callback handler to be called everytime a master polls this slave and allows a forced closure of the master connection by returning 0. More... | |
| unsigned short | getPort () |
| Returns the TCP port number used by the protocol. More... | |
Detailed Description
This class realises the server side of the MODBUS/TCP slave protocol.
It provides functions to start-up and to execute the server engine. This server engine can handle multiple master connections and is implemented as a single threaded TCP server. Upon receipt of a valid master query the server engine calls Data Provider methods to exchange data with the user application. For a more detailed description which Modbus data and control functions have been implemented in the server engine seesection Server Functions common to all Modbus Protocol Flavours.
Constructor & Destructor Documentation
◆ MbusTcpSlaveProtocol()
Instantiates a MODBUS/TCP protocol server object.
The association with a Data Provider is done after construction using the addDataTable method.
References MAX_CONNECTIONS, MasterInfo::protocol, and MasterInfo::TCP.
Member Function Documentation
◆ startupServer() [1/2]
|
inlinevirtual |
Puts the Modbus server into operation.
The server accepts connections on any interface.
This function opens a TCP/IP socket, binds the configured TCP port to the Modbus/TCP protocol and initialises the server engine.
- Note
- If the configured TCP port is below IPPORT_RESERVED (usually 1024), the process has to run with root privilege!
- Returns
- FTALK_SUCCESS on success or error code. See Error Management for a list of error codes.
Reimplemented from MbusIpServerBase.
References MbusIpServerBase::startupServer().
◆ startupServer() [2/2]
|
virtual |
Puts the Modbus server into operation.
The server accepts connections only on the interfaces which match the supplied hostname or IP address. This method allows to run different servers on multiple interfaces (so called multihomed servers).
This function opens a TCP/IP socket, binds the configured TCP port to the Modbus/TCP protocol and initialises the server engine.
- Note
- If the configured TCP port is below IPPORT_RESERVED (usually 1024), the process has to run with root privilege!
- Parameters
-
hostName String with IP address for a specific host interface or NULL if connections are accepted on any interface
- Returns
- FTALK_SUCCESS on success or error code. See Error Management for a list of error codes.
Implements MbusIpServerBase.
References FTALK_LISTEN_FAILED, FTALK_OPEN_ERR, FTALK_PORT_ALREADY_BOUND, FTALK_PORT_NO_ACCESS, FTALK_PORT_NOT_AVAIL, FTALK_SUCCESS, FTALK_TCPIP_CONNECT_ERR, MAX_CONNECTIONS, and shutdownServer().
◆ shutdownServer()
|
virtual |
Shuts down the Modbus server.
This function closes all TCP/IP connections to MODBUS/TCP masters and releases any system resources associated with the connections.
Reimplemented from MbusIpServerBase.
References MAX_CONNECTIONS, and MbusIpServerBase::shutdownServer().
◆ serverLoop()
|
virtual |
Modbus slave server loop.
This server loop must be called continuously. It must not be blocked. The server has to be started before calling the serverLoop() method.
In most cases the server loop is executed in an infinite loop in its own thread:
- Returns
- FTALK_SUCCESS on success or error code. See Error Management for a list of error codes.
Implements MbusIpServerBase.
Reimplemented in MbusRtuOverTcpSlaveProtocol.
References FTALK_FILEDES_EXCEEDED, FTALK_IO_ERROR, FTALK_SUCCESS, MAX_CONNECTIONS, readHeader(), readPayload(), and terminateSocket().
◆ setConnectionTimeOut()
| int setConnectionTimeOut | ( | long | masterTimeOut | ) |
Configures connection time-out.
This allows to detect broken TCP connections. The TCP connection is closed if a valid request is not received within the configured time period. A value of 0 disables the time-out. Default value is 0 (disabled).
- Remarks
- The time-out value is a minimum value only and the actual time may be longer. How precise it is followed depends on the operating system used, its scheduling priority and its system timer resolution.
- Parameters
-
masterTimeOut Timeout value in ms (Range: 0 - 3600000), 0 disables time-out
- Return values
-
FTALK_SUCCESS Success FTALK_ILLEGAL_ARGUMENT_ERROR Argument out of range FTALK_ILLEGAL_STATE_ERROR Server already running
References FTALK_ILLEGAL_ARGUMENT_ERROR, FTALK_ILLEGAL_STATE_ERROR, FTALK_SUCCESS, and MbusIpServerBase::isStarted().
◆ getConnectionTimeOut()
|
inline |
Returns the connection time-out setting.
- Returns
- Timeout value in ms
◆ installMasterDisconnectCallBack()
| void installMasterDisconnectCallBack | ( | void(*)(void *userData, const char *masterIpAddrSz, DisconnectReason reason) | f, |
| void * | userData | ||
| ) |
This function installs a callback handler to be called in the event of a master disconnection.
A void pointer argument can be used to pass additional data, for example a reference to the data table object or the protocol instance.
This routine can be used to implement custom time-out mechanisms.
- Parameters
-
f Callback function pointer userData A void pointer which is passed as argument to the callback.
◆ readHeader()
|
protected |
Sub-routine to read and validate the Modbus/TCP header.
- Parameters
-
sockIdx Index of socket within the connectionSocketArr
- Returns
- -1 for error, 0 for graceful socket disconnect or payload data length
◆ readPayload()
|
protected |
Sub-routine to read and validate the Modbus/TCP payload.
- Parameters
-
sockIdx Index of socket within the connectionSocketArr dataLen Length of the payload (read from MPAB header)
- Returns
- -1 for error, 0 for graceful socket disconnect
References MasterInfo::transactionId.
◆ terminateSocket()
|
protected |
Sub-routine to manage termination of connection.
- Parameters
-
sockIdx Index of socket within the connectionSocketArr reason A enum indicating why the termination occured
◆ isStarted()
|
virtualinherited |
Returns whether server has been started up.
- Return values
-
true = started false = shutdown
Implements MbusSlaveServer.
◆ setPort()
|
inherited |
Sets the TCP port number to be used by the protocol.
- Remarks
- Usually the port number remains unchanged and defaults to 502. In this case no call to this function is necessary. However if the port number has to be different from 502 this function must be called before starting the server with startupServer().
- Note
- If the configured TCP port is below IPPORT_RESERVED (usually 1024), the process has to run with root or administrator privilege!
- This parameter must be set before starting the server in order to come into effect.
- Parameters
-
portNo Port number the server shall listen on
- Return values
-
FTALK_SUCCESS Success FTALK_ILLEGAL_STATE_ERROR Server already running
References FTALK_ILLEGAL_STATE_ERROR, FTALK_SUCCESS, and MbusIpServerBase::isStarted().
◆ installIpAddrValidationCallBack()
|
inherited |
This function installs a callback handler for validating a master's IP address.
Pass a pointer to a function with checks a master's IP address and either accepts or rejects a master's connection.
- Parameters
-
f Callback function pointer userData A void pointer which is passed as argument to the callback.
- Returns
- Returns 1 to accept a connection or 0 to reject it.
◆ installMasterPollNotifyCallBack()
|
inherited |
This function installs a callback handler to be called everytime a master polls this slave and allows a forced closure of the master connection by returning 0.
This routine can be used to implement custom time-out mechanisms.
- Parameters
-
f Callback function pointer userData A void pointer which is passed as argument to the callback.
- Returns
- Returns 1 to process the poll or 0 to reject and drop the connection.
◆ getPort()
|
inlineinherited |
Returns the TCP port number used by the protocol.
- Returns
- Port number used by the protocol
◆ addDataTable()
|
inherited |
Associates a protocol object with a Data Provider and a Modbus slave ID.
- Parameters
-
slaveAddr Modbus slave address for server to listen on (-1 - 255). 0 is regarded as a valid value for a MODBUS/TCP server address. A value of -1 means the server disregards the slave address and listens to all slave addresses. 0 or -1 is only valid for MODBUS/TCP! dataTablePtr Modbus data table pointer. Must point to a Data Provider object derived from the MbusDataTableInterface class. The Data Provider is the interface between your application data and the Modbus network.
- Returns
- FTALK_SUCCESS on success or error code. See Error Management for a list of error codes.
References FTALK_ILLEGAL_ARGUMENT_ERROR, and FTALK_SUCCESS.
◆ getConnectionStatus()
|
inlineinherited |
Checks if a Modbus master is polling periodically.
- Return values
-
true = A master is polling at a frequency higher than the master transmit time-out value false = No master is polling within the time-out period
- Note
- The master transmit time-out value must be set > 0 in order for this function to work.
◆ setTimeout()
|
inherited |
Configures master activity time-out supervision.
The slave can monitor whether a master is actually polling or not. This function sets the activity time-out to the specified value. A value of 0 disables the time-out, which stops time-out notifications being sent to the Data Provider. Default value is 1000 ms.
- Remarks
- The time-out value is a minimum value only and the actual time may be longer. How precise it is followed depends on the operating system used, its scheduling priority and its system timer resolution.
- Note
- The time-out does not check whether a master is sending valid frames. The transmission of characters is sufficient to avoid the time-out.
- Parameters
-
timeOut Timeout value in ms (Range: 0 - 100000), 0 disables time-out
- Return values
-
FTALK_SUCCESS Success FTALK_ILLEGAL_ARGUMENT_ERROR Argument out of range
References FTALK_ILLEGAL_ARGUMENT_ERROR, and FTALK_SUCCESS.
◆ getTimeout()
|
inlineinherited |
Returns the currently set master activity time-out value.
- Returns
- Timeout value in ms
◆ disableExceptionReplies()
|
inherited |
Supress exception replies to be sent.
With this option only positive replies are sent to the master. All failure replies are silently discarded. This option can be useful if redundant Modbus devices are used. In this scenario supressing the reply would trigger a swap-over of the redundant devices.
◆ enableExceptionReplies()
|
inherited |
Enables exception replies after they have been turned off.
Sending exception replies in case of slave failures is the normal mode of operation.
◆ getTotalCounter()
|
inlineinherited |
Returns how often a message transfer has been executed.
- Returns
- Counter value
◆ getSuccessCounter()
|
inlineinherited |
Returns how often a message transfer was successful.
- Returns
- Counter value
◆ getPackageVersion()
|
staticinherited |
Returns the library version number.
- Returns
- Version string