Documentation
FieldTalk Modbus Master Library for .NET
MbusMasterFunctionsconfigureStandard32BitMode Method (Int32) |
Configures a slave for Standard 32-bit Mode.
Namespace: FieldTalk.Modbus.Master
Assembly: FieldTalk.Modbus.Master (in FieldTalk.Modbus.Master.dll) Version: 2.15.2-eval+3d8362b4bb861c05760d48b11d303e954bb8597c
Parameters
- slaveAddr
- Type: SystemInt32
Modbus address of slave device or unit identifier (Range: 1 - 255) A value of zero configures the behaviour for broadcasting.
Return Value
Type: Int32BusProtocolErrors.FTALK_SUCCESS on success or BusProtocolErrors.FTALK_ILLEGAL_ARGUMENT_ERROR if argument out of range
In Standard 32-bit Register Mode a 32-bit value is transmitted
as two consecutive 16-bit Modbus registers.
| This function call also re-configures the endianess to default little-endian for 32-bit values! |
| This is the default mode. |