MbusMasterFunctionsreadCoils Method (Int32, Int32, Boolean)

Modbus function 1 (01 hex), Read Coil Status/Read Coils.

Namespace:  FieldTalk.Modbus.Master
Assembly:  FieldTalk.Modbus.Master (in FieldTalk.Modbus.Master.dll) Version: 2.15.2-eval+3d8362b4bb861c05760d48b11d303e954bb8597c
Syntax
public int readCoils(
	int slaveAddr,
	int startRef,
	bool[] bitArr
)

Parameters

slaveAddr
Type: SystemInt32
Modbus address of slave device or unit identifier (Range: 1 - 255)
startRef
Type: SystemInt32
Start reference (Range: 1 - 65536)
bitArr
Type: SystemBoolean
Buffer which will contain the data read. The length of the array determines how many coils are read (Range: 1-2000).

Return Value

Type: Int32
BusProtocolErrors.FTALK_SUCCESS on success or error code. See BusProtocolErrors for possible error codes.
Remarks
Reads the contents of the discrete outputs (coils, 0:00000 table).
Note Note
No broadcast supported