Documentation

MbusTcpSlaveProtocolsetConnectionTimeOut Method

Configures connection time-out.

Namespace:  FieldTalk.Modbus.Slave
Assembly:  FieldTalk.Modbus.Slave (in FieldTalk.Modbus.Slave.dll) Version: 2.11.0-eval+eb1ecbe71c969eff5d7c05d58da16dade0474678
Syntax
public int setConnectionTimeOut(
	int masterTimeOut
)

Parameters

masterTimeOut
Type: SystemInt32
Timeout value in ms (Range: 0 - 3600000), 0 disables time-out

Return Value

Type: Int32
BusProtocolErrors.FTALK_SUCCESS on success or error code. See BusProtocolErrors for possible error codes.
Remarks
This allows to detect broken TCP connections. The TCP connection is closed if a valid request is not received within the configured time period. A value of 0 disables the time-out. Default value is 0 (disabled). The time-out value is a minimum value only and the actual time may be longer. How precise it is followed depends on the operating system used, its scheduling priority and its system timer resolution.