MbusDataTableInterfacewriteEnronRegistersTable Method

Implement this function only if your slave device has to process register ranges as Daniel/ENRON 32-bit registers.

Namespace:  FieldTalk.Modbus.Slave
Assembly:  FieldTalk.Modbus.Slave (in FieldTalk.Modbus.Slave.dll) Version: 2.11.0-eval+eb1ecbe71c969eff5d7c05d58da16dade0474678
Syntax
C#
VB
C++
Copy
protected virtual bool writeEnronRegistersTable(
	int startRef,
	int[] regArr
)
Protected Overridable Function writeEnronRegistersTable ( 
	startRef As Integer,
	regArr As Integer()
) As Boolean
protected:
virtual bool writeEnronRegistersTable(
	int startRef, 
	array<int>^ regArr
)

Parameters

startRef
Type: SystemInt32
Start register (Range: 1 - 65536)
regArr
Type: SystemInt32
Buffer which contains the received data (Length: 0 - 62)

Return Value

Type: Boolean
true indicates a successful access. The Server Engine will send a positive reply to the master.

false indicates that access has been denied or is out of range. The Server Engine will reply to the master with an exception reply message

Remarks
If a register range is processed as Daniel/ENRON register then this range is not available as normal Holding Register range.

Required: No

Default Implementation: Returns 0 which indicates that the requested register range is processed as standard Modbus registers by a subsequent call to writeHoldingRegistersTable().

Note: Daniel/ENRON is a prorietary 32-bit format which uses a non-standard Modbus frame and not understood by most master devices.
See Also

Reference

MbusDataTableInterface Class
FieldTalk.Modbus.Slave Namespace
FieldTalk Modbus Slave Library for .NET
Library version 2.11.0
Speak to the Experts
Modbus Organization Member logo

We are member of the Modbus Organization, Inc.

Buy with Confidence
30-day money back guarantee All our FieldTalk web sales are backed by a 30-day Money Back Guarantee.
We Accept
Bank VISA MasterCard PayPal
Customer Info
  • Info & Contact
  • Customer Login
  • Terms of Service
  • Terms of Sale
  • Privacy Policy
© 2005-2026 proconX Pty Ltd. All rights reserved. proconX and FieldTalk are trademarks of proconX Pty Ltd.
All other trademarks and registered trademarks appearing on www.modbusdriver.com are the property of their respective owners.