MbusDataTableInterfacewriteFileRecord Method

Override this method to implement a Data Provider function to write File Records which is Modbus function code 21 (15 hex).

Namespace:  FieldTalk.Modbus.Slave
Assembly:  FieldTalk.Modbus.Slave (in FieldTalk.Modbus.Slave.dll) Version: 2.11.0-eval+eb1ecbe71c969eff5d7c05d58da16dade0474678
Syntax
C#
VB
C++
Copy
protected virtual bool writeFileRecord(
	int refType,
	int fileNo,
	int startRef,
	short[] regArr
)
Protected Overridable Function writeFileRecord ( 
	refType As Integer,
	fileNo As Integer,
	startRef As Integer,
	regArr As Short()
) As Boolean
protected:
virtual bool writeFileRecord(
	int refType, 
	int fileNo, 
	int startRef, 
	array<short>^ regArr
)

Parameters

refType
Type: SystemInt32
Reference type (typically this is 6)
fileNo
Type: SystemInt32
File number (typically 0, 1, 3 or 4)
startRef
Type: SystemInt32
Record Number (equivalent to the start register)
regArr
Type: SystemInt16
Buffer which contains the received data

Return Value

Type: Boolean
true indicates a successful access. The Server Engine will send a positive reply to the master.

false indicates that access has been denied or is out of range. The Server Engine will reply to the master with an exception reply message

Remarks
When a slave receives a write request for function code 21 it calls this method to pass the data to the application.

Required: No

Default Implementation: Returns false which indicates to Server Engine that this address range is unsupported.

See Also

Reference

MbusDataTableInterface Class
FieldTalk.Modbus.Slave Namespace
FieldTalk Modbus Slave Library for .NET
Library version 2.11.0
Speak to the Experts
Modbus Organization Member logo

We are member of the Modbus Organization, Inc.

Buy with Confidence
30-day money back guarantee All our FieldTalk web sales are backed by a 30-day Money Back Guarantee.
We Accept
Bank VISA MasterCard PayPal
Customer Info
  • Info & Contact
  • Customer Login
  • Terms of Service
  • Terms of Sale
  • Privacy Policy
© 2005-2025 proconX Pty Ltd. All rights reserved. proconX and FieldTalk are trademarks of proconX Pty Ltd.
All other trademarks and registered trademarks appearing on www.modbusdriver.com are the property of their respective owners.