FieldTalk Modbus Master Library for .NET
MbusUdpMasterProtocol Class |
MODBUS/UDP Master Protocol class
SystemObject
FieldTalk.Modbus.MasterMbusMasterFunctions
FieldTalk.Modbus.MasterMbusIpClientBase
FieldTalk.Modbus.MasterMbusUdpMasterProtocol
FieldTalk.Modbus.MasterMbusMasterFunctions
FieldTalk.Modbus.MasterMbusIpClientBase
FieldTalk.Modbus.MasterMbusUdpMasterProtocol
Namespace: FieldTalk.Modbus.Master
Assembly: FieldTalk.Modbus.Master (in FieldTalk.Modbus.Master.dll) Version: 2.15.2-eval+3d8362b4bb861c05760d48b11d303e954bb8597c
The MbusUdpMasterProtocol type exposes the following members.
| Name | Description | |
|---|---|---|
| MbusUdpMasterProtocol | Creates new instance |
| Name | Description | |
|---|---|---|
| hostName | Host name (Inherited from MbusIpClientBase.) | |
| pollDelay | Poll delay property (Inherited from MbusMasterFunctions.) | |
| port | TCP port property (Overrides MbusIpClientBaseport.) | |
| retryCnt | Retry count property (Inherited from MbusMasterFunctions.) | |
| timeout | Time-out port property (Inherited from MbusMasterFunctions.) |
| Name | Description | |
|---|---|---|
| adamSendReceiveAsciiCmd | Send/Receive ADAM 5000/6000 ASCII command. | |
| closeProtocol | Closes an open protocol including any associated communication
resources (COM ports or sockets). (Inherited from MbusMasterFunctions.) | |
| configureBigEndianInts | Configures 32-bit int data type functions to do a word swap (Inherited from MbusMasterFunctions.) | |
| configureBigEndianInts(Int32) | Configures 32-bit int data type functions to do a word swap
on a per slave basis (Inherited from MbusMasterFunctions.) | |
| configureCountFromOne | Configures the reference counting scheme to start with one for
all slaves. (Inherited from MbusMasterFunctions.) | |
| configureCountFromOne(Int32) | Configures the reference counting scheme to start with one for
a slave. (Inherited from MbusMasterFunctions.) | |
| configureCountFromZero | Configures the reference counting scheme to start with
zero for all slaves. (Inherited from MbusMasterFunctions.) | |
| configureCountFromZero(Int32) | Configures the reference counting scheme to start with
zero for a slave. (Inherited from MbusMasterFunctions.) | |
| configureEnron32BitMode | Configures all slaves for Daniel/ENRON 32-bit Mode. (Inherited from MbusMasterFunctions.) | |
| configureEnron32BitMode(Int32) | Configures a slave for Daniel/ENRON 32-bit Mode. (Inherited from MbusMasterFunctions.) | |
| configureIeeeFloats | Configures float data type functions NOT to do a word swap (Inherited from MbusMasterFunctions.) | |
| configureIeeeFloats(Int32) | Configures float data type functions NOT to do a word swap
on a per slave basis (Inherited from MbusMasterFunctions.) | |
| configureLittleEndianInts | Configures 32-bit int data type functions NOT to do a word swap (Inherited from MbusMasterFunctions.) | |
| configureLittleEndianInts(Int32) | Configures 32-bit int data type functions NOT to do a word swap
on a per slave basis (Inherited from MbusMasterFunctions.) | |
| configureStandard32BitMode | Configures all slaves for Standard 32-bit Mode. (Inherited from MbusMasterFunctions.) | |
| configureStandard32BitMode(Int32) | Configures a slave for Standard 32-bit Mode. (Inherited from MbusMasterFunctions.) | |
| configureSwappedFloats | Configures float data type functions to do a word swap (Inherited from MbusMasterFunctions.) | |
| configureSwappedFloats(Int32) | Configures float data type functions to do a word swap
on a per slave basis (Inherited from MbusMasterFunctions.) | |
| customFunction | User Defined Function Code (Inherited from MbusMasterFunctions.) | |
| Dispose | Releases any associated communication resources (serial ports or sockets). (Inherited from MbusMasterFunctions.) | |
| forceMultipleCoils(Int32, Int32, Boolean) | Modbus function 15 (0F hex), Force Multiple Coils. (Inherited from MbusMasterFunctions.) | |
| forceMultipleCoils(Int32, Int32, Boolean, Int32) | Modbus function 15 (0F hex), Force Multiple Coils. (Inherited from MbusMasterFunctions.) | |
| getPollDelay | Returns the poll delay time (Inherited from MbusMasterFunctions.) | |
| getPort | Returns the TCP port number used by the protocol. (Inherited from MbusIpClientBase.) | |
| getRetryCnt | Returns the automatic retry count (Inherited from MbusMasterFunctions.) | |
| getSuccessCounter | Returns how often a message transfer was successful (Inherited from MbusMasterFunctions.) | |
| getTimeout | Returns the current time-out setting (Inherited from MbusMasterFunctions.) | |
| getTotalCounter | Returns how often a message transfer has been executed (Inherited from MbusMasterFunctions.) | |
| isOpen | Returns whether the protocol is open or not. (Inherited from MbusMasterFunctions.) | |
| maskWriteRegister | Modbus function 22 (16 hex), Mask Write Register. (Inherited from MbusMasterFunctions.) | |
| openProtocol | Connects to a TCP slave. (Inherited from MbusIpClientBase.) | |
| openProtocol(String) | Connects to a TCP slave. (Inherited from MbusIpClientBase.) | |
| readCoils(Int32, Int32, Boolean) |
Modbus function 1 (01 hex),
Read Coil Status/Read Coils.
(Inherited from MbusMasterFunctions.) | |
| readCoils(Int32, Int32, Boolean, Int32) |
Modbus function 1 (01 hex),
Read Coil Status/Read Coils.
(Inherited from MbusMasterFunctions.) | |
| readDeviceIdentification | Modbus function 43 (hex 2B) subfunction 14 (hex 0E), Read Device Identification (Inherited from MbusMasterFunctions.) | |
| readExceptionStatus | Modbus function 7 (07 hex), Read Exception Status. (Inherited from MbusMasterFunctions.) | |
| readFileRecord(Int32, MbusMasterFunctionsFileSubRequest) |
Modbus function 20, Read File Record.
(Inherited from MbusMasterFunctions.) | |
| readFileRecord(Int32, Int32, Int32, Int32, Int16) |
Modbus function 20, Read File Record.
(Inherited from MbusMasterFunctions.) | |
| readInputDiscretes(Int32, Int32, Boolean) |
Modbus function 2 (02 hex),
Read Inputs Status/Read Input Discretes.
(Inherited from MbusMasterFunctions.) | |
| readInputDiscretes(Int32, Int32, Boolean, Int32) |
Modbus function 2 (02 hex),
Read Inputs Status/Read Input Discretes.
(Inherited from MbusMasterFunctions.) | |
| readInputMod10000(Int32, Int32, Int32) | Modbus function 4 (04 hex) for 32-bit modulo-10000 long int data types,
Read Input Registers as modulo-10000 long int data. (Inherited from MbusMasterFunctions.) | |
| readInputMod10000(Int32, Int32, Int32, Int32) | Modbus function 4 (04 hex) for 32-bit modulo-10000 long int data types,
Read Input Registers as modulo-10000 long int data. (Inherited from MbusMasterFunctions.) | |
| readInputRegisters(Int32, Int32, Array) |
Modbus function 4 (04 hex),
Read Input Registers (16-bit, 32-bit, 64-bit and floating point single and double).
(Inherited from MbusMasterFunctions.) | |
| readInputRegisters(Int32, Int32, Array, Int32) |
Modbus function 4 (04 hex),
Read Input Registers (16-bit, 32-bit, 64-bit and floating point single and double).
(Inherited from MbusMasterFunctions.) | |
| readMultipleMod10000(Int32, Int32, Int32) |
Modbus function 3 (03 hex) for 32-bit modulo-10000 long int data types,
Read Holding Registers/Read Multiple Registers as modulo-10000 long int
data.
(Inherited from MbusMasterFunctions.) | |
| readMultipleMod10000(Int32, Int32, Int32, Int32) |
Modbus function 3 (03 hex) for 32-bit modulo-10000 long int data types,
Read Holding Registers/Read Multiple Registers as modulo-10000 long int
data.
(Inherited from MbusMasterFunctions.) | |
| readMultipleRegisters(Int32, Int32, Array) |
Modbus function 3 (03 hex),
Read Holding Registers (16-bit, 32-bit, 64-bit and floating point single and double).
(Inherited from MbusMasterFunctions.) | |
| readMultipleRegisters(Int32, Int32, Array, Int32) |
Modbus function 3 (03 hex),
Read Holding Registers (16-bit, 32-bit, 64-bit and floating point single and double).
(Inherited from MbusMasterFunctions.) | |
| readWriteRegisters(Int32, Int32, Int16, Int32, Int16) | Modbus function 23 (17 hex), Read/Write Registers. (Inherited from MbusMasterFunctions.) | |
| readWriteRegisters(Int32, Int32, Int16, Int32, Int32, Int16, Int32) | Modbus function 23 (17 hex), Read/Write Registers. (Inherited from MbusMasterFunctions.) | |
| resetSuccessCounter | Resets successful message transfer counter (Inherited from MbusMasterFunctions.) | |
| resetTotalCounter | Resets total message transfer counter (Inherited from MbusMasterFunctions.) | |
| restartCommunicationsOption | Modbus function code 8, sub-function 01, Restart Communications Option (Inherited from MbusMasterFunctions.) | |
| returnQueryData | Modbus function code 8, sub-function 00, Return Query Data. (Inherited from MbusMasterFunctions.) | |
| setClosingTimeout | Configures socket close time-out (Inherited from MbusIpClientBase.) | |
| setPollDelay | Poll delay property (Inherited from MbusMasterFunctions.) | |
| setPort | Sets the TCP port number of the Modbus slave device. (Overrides MbusIpClientBasesetPort(Int16).) | |
| setRetryCnt | Configures the automatic retry setting (Inherited from MbusMasterFunctions.) | |
| setTimeout | Configures time-out (Inherited from MbusMasterFunctions.) | |
| writeCoil | Modbus function 5 (05 hex), Force Single Coil/Write Coil. (Inherited from MbusMasterFunctions.) | |
| writeFileRecord(Int32, MbusMasterFunctionsFileSubRequest) |
Modbus function 21, Write File Record.
(Inherited from MbusMasterFunctions.) | |
| writeFileRecord(Int32, Int32, Int32, Int32, Int16) |
Modbus function 21, Write File Record.
(Inherited from MbusMasterFunctions.) | |
| writeMultipleMod10000(Int32, Int32, Int32) |
Modbus function 16 (10 hex) for 32-bit modulo-10000 long int data types,
Preset Multiple Registers/Write Multiple Registers with
modulo-10000 long int data.
(Inherited from MbusMasterFunctions.) | |
| writeMultipleMod10000(Int32, Int32, Int32, Int32) |
Modbus function 16 (10 hex) for 32-bit modulo-10000 long int data types,
Preset Multiple Registers/Write Multiple Registers with
modulo-10000 long int data.
(Inherited from MbusMasterFunctions.) | |
| writeMultipleRegisters(Int32, Int32, Array) |
Modbus function 16 (10 hex),
Write Multiple Registers (16-bit, 32-bit, 64-bit and floating point single and double).
(Inherited from MbusMasterFunctions.) | |
| writeMultipleRegisters(Int32, Int32, Array, Int32) |
Modbus function 16 (10 hex),
Write Multiple Registers (16-bit, 32-bit, 64-bit and floating point single and double).
(Inherited from MbusMasterFunctions.) | |
| writeSingleRegister(Int32, Int32, Int16) |
Modbus function 6 (06 hex),
Preset Single Register/Write Single Register.
(Inherited from MbusMasterFunctions.) | |
| writeSingleRegister(Int32, Int32, UInt16) |
Modbus function 6 (06 hex),
Preset Single Register/Write Single Register.
(Inherited from MbusMasterFunctions.) |
This class realises a Modbus client using MODBUS
over UDP protocol variant. It provides functions to
establish a UDP connection to the slave as well as data and
control functions which can be used after a connection to a
slave device has been established successfully. The data and
control functions are organized into different conformance
classes.
It is possible to instantiate multiple instances of this class for establishing multiple connections to either the same or different hosts.